Sign In | Join Free | My wneducation.com
China Xi'an Kacise Optronics Co.,Ltd. logo
Xi'an Kacise Optronics Co.,Ltd.
Kacise, understanding your automation needs.
Verified Supplier

6 Years

Home > Electromagnetic Flow Meter >

GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement

Xi'an Kacise Optronics Co.,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment

GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement

Brand Name : KACISE

Model Number : GXEFM2000

Certification : CE

Place of Origin : China

MOQ : 1 Piece

Price : Negotiable

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram,paypal

Supply Ability : 1000 Pieces per Week

Delivery Time : 5-8 work days

Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available

Flow range : 0.15... 15m/s ; 0.02...+40ft/s

Measurement range : -12…+12m/s /-40...+40ft/s

Electrical conductivity : ≥300μs/cm

Temperature : +10~+30℃/+50~+80℉

Stroage temperature : -20~70℃

Ambient temperature : -20~+60℃

Power supply : 110~240Vac

Signal Output : 4~20mA/Pulse

Electrode Material : SS316L

Explanation-Diameter : 1500mm

Contact Now

Electromagnetic Flow Meters Can Match with Computer for Fluid Measurement Range Rate 20:1

GXEFM2000 Series Electromagnetic Flow Meter

1.Description
GXEFM2000 series electromagnetic flow meters are intended for fluid measurement in most industries including water, wastewater, food and beverage, pharmaceutical and chemical.
There are two basic components of electromagnetic flow meter.
The advantages of EFM2000 series electromagnetic flow meters are as follows.
1:No obstacle existed in the measuring tube, so the pressure loss is zero, hardly blocked.
2:The request of anticorrosion, wear resistance can be satisfied, if the proper electrodes and lining material are adopt.
3:The measuring results have no relation with the physical parameters of liquid, such as pressure, temperature. Density viscosity, conductivity rate, etc. It is not influenced by the circumstances, so the accuracy is high, working process is stable and reliable.
4: Adopt the dual row flow indicator of back lighted dot array, display the instantaneous and accumulative volume, simultaneously, also displays the working status, parameters, measuring units, etc.
5: The measuring range is available of this flow meter is wide, lt's range rate normally is 20:1, generally can reach 150:1.
6: This flow meter has multi-type outputs, can be matched with computer, combined instrument unit, can meet the requirements of printing, communication and networking.

2.Technical Data

Measuring system

Measuring principle

Faraday’s law

Application range Electrically conductive fluids
Measured Value
Primary measured value Flow velocity
Secondary measured value Volume flow
Flow range

0.15... 15m/s ;

0.02...+40ft/s

Flow medium attribution

Electrical conductivity: ≥5μs/cm

Medium temperature range -20 to 392˚F(-29 to 200˚C) Transient 480 ˚F(250 ˚C)

Almost all kinds of acid alkali liquid

Transmitter Selection

260E is a split type electromagnetic Transmitter. 260D and 260A are compact type transmitter.

Transmitter General characteristics
GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement Infrared handing telecontrol keyboard,all the functions of far-untouched controlling converter.
HART/Analog and Pulse outputs available, Modbus-RTU RS-485 and Pulse output available, Profibus-DP available
Alarm OC outputs available, Empty pipe flow rate abnormal alarm available
Recording time when power turn-off, to record power broken time of instrument system automatically and recruit to count the missing flux;Recording function of hour gross, to record the flux gross by hour, fit for timed measure;
Multi language panel available.

GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement

Infrared handing telecontrol keyboard,all the functions of far-untouched controlling converter.
  • 85V--250VAC and16V--36VDC;power supply available
Multi language panel available
GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement Recording function of hour gross, to record the flux gross by hour, fit for timed measure;
GPRS wireless communication available with battery power supply
Multi language panel available.

GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement

support multi sensors for 1 transmitter
special for process control industry application
Multi language panel available.

Sensor type

The pipe diameter of sensor is available from 15mm to 3000mm. choose the proper pipe diameter and size of the application field.

GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement

GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement

GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement

Norminal Diamter (mm)

Max Process Pressure MPa* L D D0 H h n-Ø
10 4.0 150 90 60 220 102 4-Ø14
15 150 95 65 222 106 4-Ø14
20 150 105 75 230 110 4-Ø14
25 150 115 85 235 115 4-Ø14
32 150 140 100 255 122 4-Ø18
40 150 150 110 260 127 4-Ø18
50 200 165 125 270 140 4-Ø18
65 200 185 145 275 148 8-Ø18
80 200 200 160 280 154 8-Ø18
100 1.6 250 220 180 290 163 8-Ø18
125 250 250 210 320 175 8-Ø18
150 300 285 240 330 200 8-Ø22
200 1.0 350 340 295 340 220 8-Ø22
250 400 395 350 360 240 12-Ø22
300 500 445 400 405 285 12-Ø22
350 500 505 460 440 30 16-Ø22
400 600 565 515 470 350 16-Ø26
450 600 615 565 500 380 20-Ø26
500 600 670 620 530 410 20-Ø26
600 600 780 725 590 470 20-Ø30
700 700 895 840 650 530 24-Ø30
800 800 1015 950 720 600 24-Ø33
900 900 1115 1050 770 650 28-Ø33
1000 1000 1405 1160 830 700 28-Ø36
1200 0.6 1200 1405 1340 950 800 32-Ø33
1400 1400 1630 1560 1050 900 36-Ø36
1600 1600 1830 1760 1150 1000 40-Ø36
1800 1800 2040 1970 1250 1100 44-Ø39
2000 2000 2265 2180 1350 1200 48-Ø42
2200 0.25 2200 2405 2340 1450 1300 52-Ø33

* higher pressure can be specially ordered, there are no product in storage.

Liner Material Selection

Liner Notes Temp limits Type and Line size

GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement

Neoprene Typically applied to water and sea water. Abrasion resistant to slurries with small particles.

0 to 185˚F

(-18 to 85˚C)

DN 50 - 2000

2 - 80 inch

GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement Polyurethane Typically applied to slurry (no chemicals). Abrasion resistant to slurries with small particles. special for slurry and chemical slurry

0 to 140˚F

(-18 to 60˚C)

DN15 - 900

0.5 - 36 inch

GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement FVMQ Typically for high temperature waters, Abrasive resistance, but anti-corrosiveness performance not well

0 to 392˚F

(-18 to 200˚C)

Transient 250 ˚C

DN50-1200

2-50inch

GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement F4(PTFE)

BETTER FLUOROPOLYMER

More cost effective than PFA. Excellent chemical resistance, but less abrasion resistance than PFA.

-20 to 350˚F

(-29 to 177˚C)

DN10 -1600

0.4 -63inch

GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement PFA

BEST FLUOROPOLYMER

Excellent resistance to chemicals and abrasion. Suitable for any application.

-20 to 350˚F

(-29 to 177˚C)

DN10 – 400

0.4-16 inch

GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement ETFE

GOOD FLUOROPOLYMER

Similar chemical and abrasion resistance to PTFE, but a lower maxium temperature and more expensive.

-20 to 300˚F

(-29 to 149˚C)

Flanged 15–3000mm

0.5 - 115 inch

Wafer 15 - 200mm

0.5 - 8inch

Electrode Material Selection

Material Application Description
316LSST Standard electrode material. Compatible with most low concentration water based applications. Avoid using stainless in higher concentration acid applications. Such as municipal water supply, Industrial water supply, groundwater process, weak corrosive chemical fluid
Hastelloy B Ideal for hydrochloric acid(concentration lower than10% v/v),phosphate, organic acids, sodium hydroxide.
Hastelloy C276 Use in medium to high concentration acids where SST is not acceptable. Use in applications with high chloride concentrations, such as sea water,
Platinum Ideal for liquor applications found in pulp and paper industry. Also ideal as a spare electrode option to cover nearly every application in a plant. Compatible with nearly every process fluid.
Tantalum Ideal for high concentration acid flows such as hydrochloric and hydrofluoric acids.
Titanium Ideal for high concentration caustic (base) applications such as sodium and potassium hydroxides.
wolfram carbide

Ideal for paper pulp, sewage some kind of slurry with micro particles;

Not proper for Inorganic acid, Organic acids, oxide fulid.

Ask for suggestion before ordering about the Electrode Material needed

3.Ordering information

Model Suffix Code   Description
GXEFM2000 -1200 -Com -4mA -Hart -DC -Pt -Teflon1 -GR -D1400 -Exd IIC T6 Gb  
Diameter -XXXX                   Four Digitals: for example:0010: 10mm: 0015:15mm 0100: 100mm 1000: 1000mm
Transmitter -Com                 Compact type
-Rem                 Remote type
-Bat                 Battery power supply type
-PRO                 process control type
Signal Outpt -N               No output
-4mA               4-20mA
-Pul               1~5KHz pulse
-4Pul               4~20mA / 1~5KHz
Communication -N             No communication
-Hart             HART
-MOD             MODBUS-RTU
-PRO             PROFIBUS
-GPRS             GPRS net
-CDMA             CDMA net
-WHRT             Wireless HART
-Other             special order
Power Supply -AC           85V~250Vac@46~63Hz
nominal 20W
-DC           20~36VDC nominal 20W
-Bat           Battery power supply
-Bat+           Battery +12Vdc dual power supply
Other           special request
Electorde Material -316L         Stainless steel 316L
-HasB         Hastelloy B
-HasC         Hastelloy C276
-Pt         Platinum
-Ta         Tantalum
-Ti         Titanium
-WC         wolfram carbide
Liner material -Rub1       Neoprene(-20-60℃)
-Rub2       Neoprene(-20-90℃)
-Tef1       polytetrafluroethylene(-30-120℃)
-Tef2       polytetrafluroethylene(-20-160℃)
-P       Polyurethane
-FVMQ       FVMQ
-PFA       DFA
-ETFE       Ethylene tetraflurorethylene
Grounding Ring -N     No grounding ring
-GR     Grounding ring
-GE     Grounding Electrode
Wet part Connection attribute -DXX   DXX: D06, D10, D16, D25,D40 D06: DIN PN6:
D10: DIN PIN10D16: DIN PN16; D25: DIN PN25 D40: DIN PN40 etc
-AX   AX: A1, A3, A6 A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600#
-JX   JX: J1, J2, J3 J1: JIS10K;
J2: JIS 20K; J3: JIS 30K
-WF   Wafer connection (available for DN2.5; DN6 flow meter) Body material: stainless steel
-TR   Tri-Clamp for sanitary type (Body material: stainless steel)
Explosive-proof grade -Exd IIC T6 Gb Exd IIC T6 Gb
-N don't need


Product Tags:

wastewater flow meter

      

electromagnetic water flow meter

      
Buy cheap GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement product

GXEFM2000 Series Electromagnetic Water Meter / Effluent Flow Meter For Fluid Measurement Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 

Friendly Links: www.everychina.com

Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

Copyright © 2009 - 2024 wneducation.com. All rights reserved.